Detection Settings

Active

The Active menu controls the relevant settings for when using Ubidium as an Active System.

Channel

Set the Channel ID to be used for Active Timing.

Loop ID

Set the Loop ID to be used for Active Timing.

Power

Set the Loop Power to be used for the loop connected via the Active Loop Port.

Trigger Impulse

Controls how markers are generated when using either the START button or a device connected through the Trigger Port. 

(First) Marker Number

Each marker is generated with a number which is stored as the transponder code in the passing record, this can be up to 7 digits

This is the first number used if Increase Marker Number is set to Yes. 

Increase Marker Number

If set to YES then the marker number used will increase with each subsequent marker set. 

Dead Time

Dead time sets the minimum time for which the system will wait before accepting a subsequent impulse in milliseconds (default 50ms).

This should only be necessary to adjust if your impulse device creates multiple successive impulses which may cause problems for timing. 

Passing Indicator

The system can indicate when a passing is generated using the Status LED and / or internal speaker, by default this will both beep and blink on each passing.

There are four possible options for the passing indicator:

  • Beep + Blink
  • Beep
  • Blink
  • Nothing